Evident LogoOlympus Logo
显微镜解决方案

数字式照相机技术规格比较

Comparison Table for Camera Selection

Universal
model
Standard
model
Introductory
model
Stand-
Alone
model
B/W
model

Outstanding
performance
First-rate
Flexibility
Best lateral resolutionExcellent sensitivityExceptional Color FidelityImpressive image quality Full HD imaging For standard applicationsCost
performance
Space savingFor IR
observation

DP73XC10SC100XC50DP27UC50SC50UC30SC30DP22XM10IR
Image sensor 1/1.8 in.
Color CCD
2/3 in.
Color CCD
1/2.3 in.
Color CMOS
2/3 in.
Color CCD
2/3 in.
Color CCD
2/3 in.
Color CCD
1/2.5 in. 
Color CMOS
1/1.8 in.
Color CCD
1/2 in.
Color CMOS
1/1.8 in.
Color CCD
2/3 in.
Mono CCD
Pixel density (megapixel) 17.3*1 1.4 10.0 5.0 5.0 5.0 5.0 3.2 3.3 2.8 1.4
Frame rate (fps) 27~15 50~15 42~3.2 24.5~ 4.5 30~15 24.5~4.5 55~15 35~7 49~10 28~25 80~15
ADC*2 14bit 14bit 12bit 14bit 12bit 14bit 12 bit 14bit 10bit 12bit 14bit
Observation
Bright Condition (e.g. Brightfield)

Low light condition (e.g. Darkfield)

Very dark light condition (e.g. Fluorescence)

IR Condition

Measurement / Analysis
Find minute difference at low magnification

High accuracy measurement/ analysis

Thresholding analysis
(B/W mode)

*1 Pixel-shift
*2 Analog-to-digital converter. Actual bit depth of the camera depends on software used.
■Olympus recommendation
□Available

Projection
magnifications
Video camera
adapter
Projection area (F.N.)
DP73XC10SC100XC50DP27UC50SC50UC30SC30DP22XM10IR
1X U-TV1XC 8.8 11.0 7.0 11.0 10.7 11.0 7.1 8.8 8.0 8.8 11.0
0.63X U-TV0.63XC 14.0 17.5 11.0 17.5 17.0 17.5 11.3 14.0 12.7 14.0 -
0.5X U-TV0.5XC 17.6*3 22.0*3 13.9 22.0*3 21.4*3 22.0*3 14.2 17.6 16.0 17.6 -
0.35X U-TV0.35XC - - 19.9 - - - 20.3*3 - 22.0*3 - -

*3 Insufficient peripheral light intensity or vignetting may be distinct depending on optical system.
Practical Field of View (mm) = Projection Area (field number) / Objective Lens Magnifications
Actual camera sensitivity is dependent on the level of light reflectance from the sample. This level of light reflectance is dependent on observation method chosen and sample material.

Comparison Table for Camera Selection

Universal
model
Standard
model
Introductory
model
Stand- Alone
model

Outstanding
performance
First-rate
Flexibility
Exceptional Color FidelityFull HD imagingSpace saving

DP73XC10DP27SC50DP22
Image sensor 1/1.8 in.
Color CCD
2/3 in.
Color CCD
2/3 in.
Color CCD
1/2.5 in.
Color CMOS
1/1.8 in.
Color CCD
Pixel density (megapixel) 17.3*1 1.4 5.0 5.0 2.8
Frame rate (fps) 27~15 50~15 30~15 55~15 28~25
ADC*2 14bit 14bit 12bit 12 bit 12bit
Observation
Bright Condition
(e.g. Brightfield)
Low light condition
(e.g. Darkfield)
Very dark light condition
(e.g. Fluorescence)

IR Condition

Measurement / Analysis
Find minute difference at low magnification

High accuracy measurement/ analysis

Thresholding analysis
(B/W mode)

*1 Pixel-shift
*2 Analog-to-digital converter. Actual bit depth of the camera depends on software used.
■Olympus recommendation
□Available

Projection
magnifications
Video camera
adapter
Projection area (F.N.)
DP73XC10DP27SC50DP22
1X U-TV1XC 8.8 11.0 10.7 7.1 8.8
0.63X U-TV0.63XC 14.0 17.5 17.0 11.3 14.0
0.5X U-TV0.5XC 17.6*3 22.0*3 21.4*3 14.2 17.6
0.35X U-TV0.35XC - - - 20.3*3 -

*3 Insufficient peripheral light intensity or vignetting may be distinct depending on optical system.
Practical Field of View (mm) = Projection Area (field number) / Objective Lens Magnifications
Actual camera sensitivity is dependent on the level of light reflectance from the sample. This level of light reflectance is dependent on observation method chosen and sample material.

Comparison Table for Camera Selection

Universal modelStandard modelStand-Alone model

Outstanding performanceExceptional Color FidelitySpace saving

DP73DP27DP22
Image sensor 1/1.8 in. Color CCD 2/3 in. Color CCD 1/1.8 in. Color CCD
Pixel density (megapixel) 17.3*1 5.0 2.8
Frame rate (fps) 27~15 30~15 28~25
ADC*2 14bit 12bit 12bit
Observation
Bright Condition
(e.g. Brightfield)
Low light condition
(e.g. Darkfield)
Very dark light condition
(e.g. Fluorescence)

IR Condition

Measurement / Analysis
Find minute difference at low magnification

High accuracy measurement/ analysis

Thresholding analysis (B/W mode)

*1 Pixel-shift
*2 Analog-to-digital converter. Actual bit depth of the camera depends on software used.
■Olympus recommendation
□Available

Projection
magnifications
Video camera
adapter
Projection area (F.N.)
DP73DP27DP22
1X U-TV1XC 8.8 10.7 8.8
0.63X U-TV0.63XC 14.0 17.0 14.0
0.5X U-TV0.5XC 17.6*3 21.4*3 17.6
0.35X U-TV0.35XC - - -

*3 Insufficient peripheral light intensity or vignetting may be distinct depending on optical system.
Practical Field of View (mm) = Projection Area (field number) / Objective Lens Magnifications
Actual camera sensitivity is dependent on the level of light reflectance from the sample. This level of light reflectance is dependent on observation method chosen and sample material.