Standard Product Range | Volume |
T2 system: 20 mm–130 mm (0.79 in.–5.12 in.), 1.5 m (5 ft) approximate minimum length
T4 system: 40 mm–260 mm (1.57 in.–10.24 in.), 3 m (9 ft) approximate minimum length |
Speed | Up to 2.5 m/s (492 ft/min) | |
Coverage |
Surface inspection using a multi-layer probe arrangement
Round: 100% of circumference Square: 100%, which includes faces and corners | |
Data Presentation |
Real-Time Data
Inspection Results | C-scan, strip charts, Lissajous (XY) layouts, and alarms |
Inspection Modes | Orientation | Axially (0 degree) and radially (90 degree) oriented indications |
Bar Temperature | Up to 70 °C (158 °F) | |
Detection Capabilities for Typical Reference Defects | Size |
Surface crack size ≥0.2 mm (0.008 in.) depth × 10 mm (0.39 in.) length
Note: Minimum indication depth varies according to surface roughness and material grade |
Reporting and Data | Report Types | Setup, calibration, calibration-check, inspection, user-configurable reports |
Storage | Storage | Storage Real-time database inspection data storage—on local computer or end-user database |