Evident LogoOlympus Logo

Industrial Microscopes
Specifications

SPECIFICATIONS OF BX53M SUGGESTED CONFIGURATION FOR GENERAL USE

EntryStandardAdvanced
Optical system UIS2 optical system (infinity-corrected)
Main unit Microscope frame BX53MRF-S
(Reflected)
BX53MTRF-S
(Reflected/Transmitted)
BX53MRF-S
(Reflected)
BX53MTRF-S
(Reflected/Transmitted)
BX53MRF-S
(Reflected)
BX53MTRF-S
(Reflected/Transmitted)
Focus Stroke: 25 mm
Fine stroke per rotation: 100 μm
Minimum graduation: 1 μm
With upper limit stopper, torque adjustment for coarse handle
Max. specimen height Reflected:  65 mm (w/o spacer), 105 mm (with BX3M-ARMAD)
Reflected/Transmitted:  35 mm (w/o spacer), 75 mm (with BX3M-ARMAD)
Observation tube Wide field (F.N.22) U-TR30-2-2
Inverted: trinocular
Illumination Reflected light
Transmitted light
BX3M-KMA-S
White LED, BF/DIC/POL/MIX FS, AS (with centering mechanism), BF/DF interlocking  
BX3M-RLAS-S
Coded, White LED, BF/DF/DIC/POL/MIX FS, AS (with centering mechanism), BF/DF interlocking
BX3M-LEDT
White LED
Abbe/long working distance condensers
BX3M-LEDT
White LED
Abbe/long working distance condensers
BX3M-LEDT
White LED
Abbe/long working distance condensers
Revolving nosepiece U-5RE-2
For BF: Quintuple
U-D6BDRE
For BF/DF: Sextuple
U-D6BDRES-S
For BF/DF : Sextuple, Coded
Eyepiece(F.N.22) WHN10
WHN10X-H
MIX observation BX3M-CB
Control box
BX3M-HS
Hand switch
U-MIXR-2
MIX slider for reflected light observation
U-MIXRCBL
Cable for MIXR
Condenser (Long working distance) U-LWCDU-LWCDU-LWCD
Power cable UYCP (x1)UYCP (x2)
Weight Reflected: approx.15.8 kg (microscope frame 7.4 kg)
Reflected/transmitted: approx. 18.3 kg (microscope frame 7.6 kg)
Objectives MPLFLN set MPLFLN5X, 10X, 20X, 50X, 100X
BF/POL/FL observation
MPLFLN BD set MPLFLN5XBD, 10XBD, 20XBD, 50XBD, 100XBD
BF/DF/DIC/POL/FL  observation
MPLFLN-BD, LMPLFLN-BD set MPLFLN5XBD, 10XBD, LMPLFLN20XBD, 50XBD, 100XBD
BF/DF/DIC/POL/FL  observation
MPLFLN-BD, MXPLFLN-BD, LMPLFLN-BD set MPLFLN5XBD, 10XBD, MXPLFLN20XBD, 50XBD, LMPLFLN20XBD, 50XBD, 100XBD
BF/DF/DIC/POL/FL observation
Stage (X x Y) 76 mm x 52 mm set U-SVRM, U-MSSP
Coaxial right handle stage / 76 (X) × 52 (Y) mm, with torque adjustment
100 mm x 10 0mm set U-SIC4R2, U-MSSP4
Large-size coaxial right handle stage / 100 (X) x 100 (Y) mm, with lock mechanism in Y axis
100 mm x 100 (G) mm set U-SIC4R2, U-MSSPG
Large-size coaxial right handle stage / 100 (X) x 100 (Y) mm, with lock mechanism in Y axis (Glass plate)
150 mm x 100 mm set U-SIC64, U-SHG, U-SP64
Large-size coaxial right handle stage / 150 (X) x 100 (Y) mm, with torque adjustment, with lock mechanism in Y axis
150 mm x 100 (G) mm set U-SIC64, U-SHG, U-SPG64
Large-size coaxial right handle stage / 150 (X) x 100 (Y) mm, with torque adjustment, with lock mechanism in Y axis (Glass plate)
Option MIX observation set* BX3M-CB, BX3M-HS, U-MIXR-2, U-MIXRCBL
DIC* U-DICR
Intermediate Tubes U-CA, U-EPA2, U-TRU
Filters U-25ND6, U-25ND25, U-25LBD, U-25LBA, U-25Y48, U-AN360-3, U-AN360P, U-PO3, U-25IF550, U-25L42, U-25, U-25FR
Filter for condenser 43IF550-W45, U-POT
Stage plate U-WHP64, BH2-WHR43, BH2-WHR65, U-WHP2
Specimen holder U-HRD-4, U-HLD-4, U-HRDT-4, U-HLDT-4
Handle rubber U-SHG, U-SHGT

*Cannot be used with U-5RE-2.

BX53M / BXFM ESD UNITS

Items Microscope frame BX53MRF-S, BX53MTRF-S
Illuminator BX3M-KMA-S, BX3M-RLA-S, BX3M-URAS-S, BX3M-RLAS-S
Nosepiece U-D6BDREMC, U-D6BDRES-S, U-D5BDREMC-ESD, U-5RES-ESD
Stage U-SIC4R2, U-MSSP4

SPECIFICATIONS OF BX53M SUGGESTED CONFIGURATION FOR DEDICATED USE

FluorescenceInfraredPolarized
Optical system UIS2 optical system (infinity-corrected)
Main unit Microscope frame BX53MRF-S
(Reflected)
BX53MTRF-S
(Reflected/ Transmitted)
BX53MRF-S
(Reflected)
BX53MTRF-S
(Reflected/Transmitted)
Focus Stroke: 25 mm
Fine stroke per rotation: 100 μm
Minimum graduation: 1 μm
With upper limit stopper, torque adjustment for coarse handle
Max. specimen height Reflected:  65 mm (w/o spacer), 105 mm (with BX3M-ARMAD)
Reflected/Transmitted:  35 mm (w/o spacer), 75 mm (with BX3M-ARMAD)
Observation tube Wide field (F.N.22) U-TR30-2
Inverted: trinocular
U-TR30IR
Inverted: trinocular for IR
U-TR30-2
Inverted: trinocular
Polarized Light Intermediate Attachment (U-CPA) Bertrand Lens Focusable
Bertrand Field Stop ø3.4 mm diameter (fixed)
Engage or disengage Bertrand lens changeover between orthoscopic and conoscopic observation Position of slider ● in
Position of slider ○ out 
Analyzer Slot Rotatable Analyzer with Slot (U-AN360P-2)
Illumination Reflected light FL observation BX3M-URAS-S
Coded universal reflected light, 4 position mirror unit turret, (standard: U-FWUS, U-FWBS, U-FWGS, U-FBF etc) With FS, AS (with centering mechanism), With shutter mechanism
IR observation BX3M-RLA-S
100W halogen lamp for IR, BF/IR, AS (with centering mechanism)
U-LH100IR (Including 12V 10W HAL-L)
100W Halogen light source for IR
TH4-100
100W power supply
TH4-HS
Hand switch
U-RMT
Extension cord
Transmitted light POL observation BX3M-LEDT
White LED
Abbe/long working distance condensers
Revolving nosepiece U-D6BDRES-S
For BF/DF : Sextuple, Coded
U-5RE-2
For BF : Quintuple
U-P4RE
Quadruple, centerable attachable components
1/4 wavelength retardation plate (U-TAD), tint plate (U-TP530) and various compensators can be attached using plate adapter (U-TAD)
Eyepiece(F.N.22) WHN10X
WHN10X-HCROSS-WHN10X
Mirror units U-FDF
For DF
U-FBFL
For BF, built-in ND filter
U-FBF
For BF, detachable ND filter
U-FWUS
For Ultra Violet-FL
U-FWBS
For Blue-FL
U-FWGS
For Green-FL
Filter / Polarizer / Analyzer U-25FR
Frost filter
U-BP1100IR/U-BP1200IR
Band path filters for IR
43IF550-W45
Green filter
U-POIR
Reflected polarizer slider for IR
U-AN360IR
Rotatable analyzer slider for IR
U-AN360P-2
360° Dial-rotatable
Rotatable minimum angle 0.1°
Condenser U-LWCD
Long working distance
U-POC-2
Achromat strain-free condenser.
360°rotatable polarizer with swing-out achromatic top-lens.
Click stop at position "0°" is adjustable.
NA 0.9 (top-lens in) / NA 0.18 (top-lens out)
Aperture iris diaphragm: adjustable from 2 mm to 21 mm diameters
Slider / Compensators U-TAD
Slider (Plate adapter)
U-TP530
Tint plate
U-TP137
1/4 wavelength retardation plate
Power cable UYCP (x1)UYCP (x2)UYCP (x1)
Weight Reflected: approx.15.8 kg (microscope frame 7.4 kg) Reflected/transmitted: approx. 18.3 kg (microscope frame 7.6 kg)  Approx.18.9 kg (microscope frame 7.4 kg) Approx.16.2 kg (microscope frame 7.6 kg)
Reflected FL light source Light guide U-LGPS, U-LLGAD, U-LLG150, Light guide set
Mercury lamp U-LH100HGAPO1-7, USH-103OL (x2), U-RFL-T, U-RCV Mercury lamp set
Objectives MPLFLN set MPLFLN5X, 10X, 20X, 50X, 100X
BF/DIC/POL/FL observation
MPLFLN BD set MPLFLN5XBD, 10XBD, 20XBD, 50XBD, 100XBD
BF/DF/DIC/POL/FL  observation
MPLFLN-BD, LMPLFLN-BD set MPLFLN5XBD, 10XBD, LMPLFLN20XBD, 50XBD, 100XBD
BF/DF/DIC/POL/FL  observation
MPLFLN-BD, MXPLFLN-BD, LMPLFLN-BD set MPLFLN5XBD, 10XBD, MXPLFLN20XBD, 50XBD, LMPLFLN20XBD, 50XBD, 100XBD
BF/DF/DIC/POL/FL observation
IR set LMPLN5XIR,10XIR,LCPLN20XIR,50XIR,100XIR
IR observation
POL set UPLFLN4XP,10XP,20XP,40XP
POL observation
Stage (X x Y) 76 mm x 52 mm set U-SVRM, U-MSSP
Coaxial right handle stage / 76 (X) × 52 (Y) mm, with torque adjustment
100 mm x 10 0mm set U-SIC4R2, U-MSSP4
Large-size coaxial right handle stage / 100 (X) x 100 (Y) mm, with lock mechanism in Y axis
100 mm x 100 (G) mm set U-SIC4R2, U-MSSPG
Large-size coaxial right handle stage / 150 (X) x 100 (Y) mm, with lock mechanism in Y axis (Glass plate)
150 mm x 100 mm set U-SIC64, U-SHG, U-SP64
Large-size coaxial right handle stage / 150 (X) x 100 (Y) mm, with torque adjustment, with lock mechanism in Y axis
150 mm x 100 (G) mm set U-SIC64, U-SHG, U-SPG64
Large-size coaxial right handle stage / 150 (X) x 100 (Y) mm, with torque adjustment, with lock mechanism in Y axis (Glass plate)
POL set U-SRP+U-FMP
Polarizing rotatable stage + Mechanical stage
Option MIX observation set* BX3M-CB, BX3M-HS, U-MIXR-2, U-MIXRCBL
DIC* U-DICR
Intermediate Tubes U-CA, U-EPA2, U-TRU
Filters U-25ND6, U-25ND25, U-25LBD, U-25LBA, U-25Y48, U-AN360-3, U-AN360P, U-PO3, U-25IF550, U-25L42, U-25, U-25FR
Filter for condenser 43IF550-W45, U-POT
Stage plate U-WHP64, BH2-WHR43, BH2-WHR65, U-WHP2
Specimen holder U-HRD-4, U-HLD-4, U-HRDT-4, U-HLDT-4
Handle rubber U-SHG, U-SHGT

*Cannot be used with U-5RE-2