The eddy current air conditioner probes offer solid construction for durability. They include a differential bobbin set and a circumferentially sensitive pancake array. They offer better detection capability at the transition zone in addition to detection of circumferentially oriented cracks.
Heavy tube wall: TEC and TED probes are not recommended for wall thicknesses over 2.0 mm (0.08 in.), because the inspection may be limited to the inside. Note that these probes require the TE-ADP-004 adapter.
The air conditioning probe combines pancake arrays with standard differential bobbins for detection of circumferentially oriented cracks.
Use the nomenclature and the chart below to configure your part number.
Probe Type |
Probe Diameter *
(use mm in part ID) | Center Frequency |
Cable Length
(TEC only)** | |
mm | in. | |||
TEC: Attached
TED: Detachable (Use with TEZ-ACS or TEZ-ACK cables.**) | Standard TEC: 9.6 mm to 50 mm TED: 11 mm to 50 mm by 0.2 mm Custom (TEC only) 50.2 mm to 100 mm | Standard TEC: 0.378 in. to 1.969 in. TED: 0.433 in. to 1.969 in. by 0.008 in. Custom (TEC only): 1.976 in. to 3.937 in. |
015 (Low)
050 (Mid) 250 (High) 600 (Very High) |
15 m (50 ft)
20 m (65 ft) 30 m (100 ft) |
**TEZ cable information for TEB probes is available in the Tube Inspection Probe Catalog. |
您即将被转换到我们的本地网站。